Input Voltage |
11 to 16VDC |
13.5 to 16VDC |
Input Current |
14 to 11A DC |
12 to 11ADC |
Output Voltage |
28VDC |
28VDC |
Output Current |
5.0 AMPS |
6.0 AMPS |
Efficiency @ Full Load |
87% |
90% |
Output Ripple |
50 mV p-p plus input ripple |
Regulation |
2% for line, 2% load & 2% temperature Refer to graph of input vs. output voltage |
Load Transient |
2V maximum overshoot for 40 mSec |
Response |
From FL to NL 4V maximum undershoot for 10 mSec from NL to FL |
Protection (OVERLOAD) |
Output voltage collapses to input DC voltage when load exceeds approximately 6.5 to 7.5 amp
|
Protection |
Over voltage circuit limits output to approximately 33VDC |
Temperature |
-55°C to +71°C (sufficient cooling required @ +71°C ambient); 25 SCFM of air or base plate temperature held @ 71°C |
Altitude |
55,000’ |
Size |
2.3" H x 2.3" W x 5.8" L, 5.7 cm H x 5.7 cm W x 14.6 cm L |
Weight |
1.5 lbs. (683 g) |
A |
+13.75VDC input |
Up to 16VDC (see specs) |
B |
Common ground |
Input/output return |
C |
+28VDC output |
Regulated, factory set |
D |
NC |
No connection |
E |
Connected to PIN A |
Parallel to input line |
RB-125 |
MS3102A14S5P |
MS3106A14S5S |
RB-126 |
MS3102A14S5P |
MS3106A14S5S |