Input Voltage |
22 to 41 VDC (27.5 VDC nominal) |
Input Current |
18.1 ADC at full load (nominal) |
Output Voltage |
13.75 VDC |
Output Current |
30.0 ADC at full load |
Output Ripple |
13.75 mV |
Efficiency |
80% (minimum) |
Load Regulation |
1% Line, 1% Load, 1% Temperature |
Load Transient Response |
NL to FL condition: 4.0 Vp undershoot for 5.0 mSec. (nominal) FL to NL condition: 2.0 Vp overshoot for 5.0 mSec. (nominal) |
Overload Capacity |
110% of the rated output power for a period of two hours: 150% of the rated output power for a period of 5 minutes (1 min. at 70°C ambient temp.) Without damage or degradation, the converter will withstand a sustained short circuit and provide 200% of the rated output current for a period of one minute. |
Protection Circuit (Reverse Polarity) |
The converter will trip a MIL-C-5809 25 ADC input circuit breaker in the event of reverse polarity input voltage connection |
Protection Circuit (Shutdown) |
The converter will shutdown under the following conditions: Input voltage > 41 VDC (-3 VDC hysteresis) Input voltage < 15 VDC (-2 VDC hysteresis) Output voltage > 16 VDC (-2 VDC hysteresis) Internal temperature > 100°C |
Temperature |
-55°C to +71°C (-65°F to 160°F) |
Altitude |
55,000 ft. |
Size |
9.50" L x 6.9" W x 3.38" H (mounting flange included) |
Weight |
3.5 lbs |
Environmental |
DO-160C, Env. Cat. F2XBB[LV]XXXXXXXXXXXX(ZA)XXX |