Input Voltage: |
Nominal 28.0 VDC. ±2 VDC , Range 22 to 30 VDC |
Power Factor: |
.8 to -.95 |
Amplitude Distortion: |
Less than 7% |
Wave Form: |
Sine Wave |
Phase: |
Single |
Temperature: |
-65°F to +160°F (-55°C to +70°C) |
Altitude: |
55,000 ft. |
Efficiency: |
70% typical. |
Input Overvoltage: |
Withstand 130% input overvoltage for 5 min. while supplying full rated VA output power. Output voltage under this condition 115 VAC + 5% -7% |
Overload Capacity: |
Capable of 150% output current for at least 5 minutes. |
Input Voltage Protection: |
Inverter withstands transients of 88 volts lasting 1 mSec. on the 28.0 VDC input line. |
Overload & Short Circuit Protection: |
Withstand without damage or degradation loads exceeding 150% of rated output to an output short circuit. Inverter delivers rated output on removal of above condition. |
Humidity: |
Tested to greater than 95% for ten days, temperature was cycled between 75°F to 160°F. |
Environment: |
Designed to meet RTCA DO-160 env. cat. D2BR--- |